BOILER 120 mbh SSB120 HIGH EFF STAINLESS STEEL BOSCH

7738004892 MFG #: 7738004892
  • AFUE Rating: 96%, 96% Percent
  • AGA Input Rating: 119 MBH, 119420 BTU/Hour
  • Gas Type: Natural/Propane
  • Input Capacity: 120 mbh
  • Net IBR Rating: 96 MBH
Residential Condensing Boiler; Type Hot Water; Supply Connection 1 Inch Male Threaded; Return Connection 1 Inch Male Threaded; Gas Type Natural/Propane; Gas Connection 3/4 Inch Threaded; AGA Input Rating 119420 BTU/Hour; Net IBR Rating 96 MBH; AFUE Rating 96 Percent; Air Inlet Connection 2 Inch; Boiler Dimensions 20 Inch Length x 47-1/2 Inch Width x 15-3/8 Inch Height; Boiler Material Stainless Steel; Water Content 1 Gallon; Venting Type Direct; Vent Size 2 Inch; Relief Valve Details 30 PSI Pressure Relief Valve Installed; Pressure Rating 80 PSI; Mounting Type Floor Mount; Warranty 5 Year (Parts and Labor), Lifetime Limited (Heat Exchanger); Options Adapter; Inclusions/Features Integral Pump, Built-In Low Water Cut-Off, Adjustable Manual Reset High Limit, Push-Terminal Wiring and a Host of Venting Option; Applicable Standard ASME H, AHRI, CSA (Canada and US); Electrical Rating 120 Volt AC 60 Hertz 1-Phase 2 Amp Full Load; Turndown Ratio 5:1; Noise Rating 44 Decibel; Maximum Operating Temperature 194 Deg F; Water Connection 1 InchThe Buderus SSB residential boilers were designed with the same high-quality components found in our commercial SSB boilers, but in a compact space-saving design. All SSB boilers include integral pumps, built-in low water cut-offs, adjustable manual reset high limits, push-terminal wiring and a host of venting options. In addition, the Buderus SSB residential boilers have the best price-performance and warranty in the market. The 316L stainless steel heat exchanger, is a water-tube design that has no welds on the water side of the heat exchanger. This feature, combined with a 5:1 turndown pre-mix burner, allows the SSB boilers to achieve an AFUE rating of 96%. Other standard features include outdoor reset, domestic hot water priority, top connections which allow for an easy installation, limited clearance requirements, internal cascade sequencer for up to 8 boilers for increased output and application design, and CSD-1 components pre-installed.
  • Supply Connection
  • Warranty
  • Gas Connection
  • Water Content
  • Options
  • Inclusions/Features
  • AGA Input Rating
  • Air Inlet Connection
  • Venting Type
  • Relief Valve Details
  • Net IBR Rating
  • Input Capacity
  • Gas Type
  • Type
  • AFUE Rating
  • Vent Size
  • Applicable Standard
  • Boiler Dimensions
  • Pressure Rating
  • Mounting Type
  • Return Connection
  • Boiler Material
  • IsInactive
1 Inch Male Threaded
5 Year (Parts and Labor), Lifetime Limited (Heat Exchanger)
3/4 Inch Threaded
1 Gallon
Adapter
Integral Pump, Built-In Low Water Cut-Off, Adjustable Manual Reset High Limit, Push-Terminal Wiring and a Host of Venting Option
119 MBH
2 Inch
Direct
30 PSI Pressure Relief Valve Installed
96 mbh
120 mbh
Natural/Propane
Hot Water
96%
2 Inch
ASME H, AHRI, CSA (Canada and US)
20 Inch Length x 47-1/2 Inch Width x 15-3/8 Inch Height
80 PSI
Floor Mount
1 Inch Male Threaded
Stainless Steel
true